16MnCr5 EN 10084-1998, Number: 1.7131
|
Comparison of steel grades | |
JUS | Č.4320 | |
DIN | 16MnCr 5; ZF 6 | |
BS | 590M17, | |
GOST | 18HG | |
AISI | SAE 5115, SAE 51204 | |
UNI | 16MnCr5 | |
NF | 16MC5 |
Under EN10084-1998 standard,Structural 16MnCr5 steel PLATE means a specific level of strength and formability of steel. Tensile test can be formed after the interruption of the elongation said. Structural steel usually used for carrying purposes, the strength of steel in these applications is an important design criteria.Structural 16MnCr5 steel PLATE can be broken down as follows: alloy steel carbon steel.
16MnCr5 STEEL PLATE Chemical composition (cast analysis)
Chemical elements | C | Si max. |
Mn | P max. | S | Cr |
%, by mass | 0,14-0,19 | 0,40 | 1,00-1,30 | 0,035 | ≤ 0,035 | 0,80 – 1,10 |
Permissible deviation | ± 0,02 | + 0,03 | ± 0,05 | + 0,005 | + 0,005 | ± 0,05 |
Hardness limits for 16MnCr5 steel SHEET
Hardness HRC at a distance from quenched end of test piece (in milimetres) of | ||||||||||||||||
mm | 1,5 | 3 | 5 | 7 | 9 | 11 | 13 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | |
+H | max. | 47 | 46 | 44 | 41 | 39 | 37 | 35 | 33 | 31 | 30 | 29 | 28 | 27 | - | - |
min. | 39 | 36 | 31 | 28 | 24 | 21 | - | - | - | - | - | - | - | - | - | |
+HH | max. | 47 | 46 | 44 | 41 | 39 | 37 | 35 | 33 | 31 | 30 | 29 | 28 | 27 | - | - |
min. | 42 | 39 | 35 | 32 | 29 | 26 | 24 | 22 | 20 | - | - | - | - | - | - | |
+HL | max. | 44 | 43 | 40 | 37 | 34 | 32 | 30 | 28 | 26 | 25 | 24 | 23 | 22 | - | - |
min. | 39 | 36 | 31 | 28 | 24 | 21 | - | - | - | - | - | - | - | - | - |
Hardness requirements for products delivered in the conditions ’’treated to improve shearabilita’’ (+S), ’’anneled to maximum hardness requirements’’ (+A), ’’treated to hardness range’’ (+TH) or ’’treated to ferrite-pearlite structure and hardness range’’ (+FP)
Brinell hardness in the condition | ||||||
+S max. | +A max. | +TH | +FP | |||
min. | max. | min. | max. | |||
* | 207 | 156 | 207 | 140 | 187 |
Non-metallic inclusions Requirements for microscopic degree of purity when tested in accordance with DIN 50 602 (method K) (valid for oxidic non-metallic inclusions)
D (mm) Bars Diameter d (mm) | K Total characteristic value K (oxides) for the individual cast |
140 < d 200 | K 4 ≤ 50 |
100 < d ≤ 140 | K 4 ≤ 45 |
70 < d ≤ 100 | K 4 ≤ 40 |
35 < d ≤ 70 | K 4 ≤ 35 |
17 < d ≤ 35 | K 3 ≤ 40 |
8 < d ≤ 17 | K 3 ≤ 30 |
d ≤ 8 | K 2≤ 35 |
Conditions for heat treating test bars and treatment of the steels
End quenchh test Quenching, 0C | Carbunnzing temperature, 0C | Core-hardening temperature, 0C | Case-hardening temperature, 0C | Tempering, 0C |
870 | 880 to 980 | 860 to 900 | 780 to 820 | 150 to 200 |
Source:
Tags: 16MnCr5